- Testing Equipment[6]
- Boiler Parts[1]
- Boilers[5]
- Other Measuring & Analysing Instruments[6]
- Other Lab Supplies[1]
- Other Electronic Measuring Instruments[6]
- Industrial Metal Detectors[1]
- Width Measuring Instruments[3]
- Other Measuring & Gauging Tools[3]
- Gauges[3]
- Hardness Testers[2]
- Access Control System[1]
- Other Machinery[4]
- Instrument Parts & Accessories[4]
- Radiology Equipments & Accessories[6]
- Inspection & Quality Control Services[1]
- Other Access Control Products[1]
- Contact Person : Mr. Li David
- Company Name : Dandong Flaw Detector Equipment Co., Ltd.
- Tel : 86-415-2883568,13942562233
- Fax : 86-415-2825993
- Address : Liaoning,Dandong,70-2# Tianhougong St. Dandong,Liaoning,P.R.of China
- Country/Region : China
- Zip : 118000
Related Product Searches:portable ultrasonic flaw detector,High Quality,ultrasonic flaw detector, UT flaw detector,USM 35XS
portable ultrasonic flaw detector
Specifications
Calibration ranges
Min.: 0 to 0.5 mm +10 % (steel), 0 to 0.02” +10 % (steel)
Max.: 0 to 9,999 mm +10 % (steel), 0 to 390” +10 % (steel) within the frequency range from 0.2
to 1 MHz / 0.5 to 4 MHz
0 to 1,420 mm +10% (steel),
0 to 56” +10 % (steel) withinthe frequency range from 0.8to 8 MHz / 2 to 20 MHz
Sound velocity
1,000 to 15,000 m/s, 40 to 600 inch/ms variable in steps of 1 m/s, 0.1 inch/msand fixed programmed values
Display delay
From -10 to 1,000 mm, -0.3 to 40” (340 μs)
Probe delay
0 to 200 μs
Auto calibration
Measurement and setting of sound velocity and probe delay using two known calibration echoes
(2-point calibration)
Pulse intensity
220 pF, 1 nF
Damping
50 ohms, 500 ohms (1,000 ohms in TR mode)
Pulse repetition frequency
4 to 1,000 Hz, variable in 10 steps
Frequency ranges (-3 dB)
0.2 to 1 MHz / 0.5 to 4 MHz / 0.8 to 8 MHz /
2 to 20 MHz
Gain
0 to 110 dB, variable in steps
Gain steps
0.5 / 1 / 2 / 6 / 12 dB (or user-adjustable),
step 0 is locked
Fine gain
4 dB, continuously variable in 40 steps
Rectification
Full-wave, negative and positive half-wave, RF mode
Reject
Linear, 0 to 80 % screen height
Variable in steps of 1 %
Monitor gates
2 independent gates in color bar mode, start and width variable over the entire calibration range, response threshold of 10 to 90 % screen height
variable in steps of 1 % (coincidence and anti-coincidence), alarm signal via LED and connectable
internal horn, Gate A switchable as interface gate for Gate B, gate magnifier (zooming of gate range over the entire display range)
Sound path measurement
Digital display of sound path (projection distance, depth) between initial pulse and the first echo in the gate, or between the echoes in the two gates, measurement always at the intersection point with the echo flank or echo peak
Measurement resolution
0.01 mm within a range up to 99.99 mm/
0.1 mm within a range from 100 to 999.9 mm/
1 mm above 1,000 mm, 0.001” within a range up to 9.999”/
0.01” above 10”
With evaluation in the frozen A-scan: 0.5 % of the calibration range setting
Amplitude display
In % screen height
USM 35X DAC: additionally in dB above DAC or TCG
USM 35X S: additionally in dB above DGS curve
or ERS
Displayed reading
Sound path, (reduced) projection distance, depth, amplitude for every gate, userconfigurable
at four positions of measurement line and of the zoomed display in the A-scan
A-scan functions
Manual or automatic A-scan freeze, A-scan comparison, echo dynamics(envelope), peak echo storage
Color functions
Patented color-coded display of legs in angle testing, adaptation of background color to the light conditions of test environment, color display of monitor gates and of registration curves (DAC, TCG, DGS) for direct recognition, messages and alarms in red characters
DAC / TCG (Option)
Only USM 35X DAC and USM 35X S: Distance-Amplitude Curves (DAC) or TCG line (TCG) with a maximum of 10 reference echoes, 4 other curves or lines can be displayed with variable dB intervals. JIS DAC can be selected in order to allow inspection acording to JIS Z3060-2002(Japanese Inspection Standard). Automatic gain control during DAC recording.
DGS (Option)
Only USM 35X S: DGS curves for single-element and dual-element probes (B1S, B2S, B4S, MB2S, MB4S, MB5S, WB…-1, WB…-2, SWB…-2, SWB…-5, MWB…-2, MWB…-4, SEB and MSEB) and for all materials, sound attenuation and transfer loss correction, 4 other curves can be displayed with variable dB intervals
Display size / resolution
116 mm x 87 mm, 4.6" x 3.4" (W x H)
320 x 240 pixels
A-scan size / resolution
116 mm x 80 mm, 4.6” x 3.2”
320 x 220 pixels (zoom)
Data memory
800 instrument setups or reports, including AScans can be stored, recalled, printed or exported
to a computer.
RS 232 interface
9-pin DSUB, bi-directional, 300 - 57,600 baud
An USB adapator cable can be provided to connect the USM 35X to a computer that does not have RS 232 port
Input/Output
8-way Lemo-1 socket (trigger output, gate alarm, test data release)
Additional analog output for amplitude or sound path in selected gate
VGA output
10-way Lemo-1 socket for the connection of an external display screen or beamer
Dialog languages
German, English, French, Italian, Portuguese, Spanish, Danish, Swedish, Norwegian, Finnish, Czech, Slovenian, Romanian, Dutch, Croatian, Hungarian, Russian, Polish, Slovakian, Japanese
Weight
2.2 kg, 4.9 lbs., including batteries
Size
177 mm x 255 mm x 100 mm, 7.0" x 10" x 3.9" (H x W x D)
portable ultrasonic flaw detector