Dandong Flaw Detector Equipment Co., Ltd.
Main products:X-Ray Machine,X-Ray Generator,X-Ray Flaw Detector,Controller,X-Ray Flaw Detector Control Unit
Products
Contact Us
  • Contact Person : Mr. Li David
  • Company Name : Dandong Flaw Detector Equipment Co., Ltd.
  • Tel : 86-415-2883568,13942562233
  • Fax : 86-415-2825993
  • Address : Liaoning,Dandong,70-2# Tianhougong St. Dandong,Liaoning,P.R.of China
  • Country/Region : China
  • Zip : 118000

Complete Ultrasonic Testing Machine

Complete Ultrasonic Testing Machine
Product Detailed
1.Complete Ultrasonic Testing Machine 2.Epoch_XT 3.USB Port 4.Multicolor LCD 5.EN12668-1

Testing Machine

EPOCH XT Specifications

GENERAL

EN12668-1 Compliant

Weight: 2.1 kg (4.7 lb) with lithium-ion battery

Dimensions (H x W xD): 277 mm x 150 mm x 51 mm (at hand), 71 mm (at display); 10.9 in. x 5.9 in. x 2 in. (at hand), 2.8 in. (at display)

Keypad: English, International, Japanese, or Chinese

Languages: English, Spanish, French, German,Italian, Japanese, Chinese, Russian, Korean, Norwegian, Swedish

Transducer Connections: BNC or Number 1 LEMO

Battery: Choice of lithium-ion, nickel metal hydride, and alkaline C-cells

Battery Operating Time: Lithium ion: 9 to 10 hoursNiMH: 5 hours; C-cells: 1 to 2 hours

Power Requirements: AC Mains: 100 VAC to 120 VAC, 200 VAC to 240 VAC, 50 Hz to 60 Hz

ENVIRONMENTAL RATINGS

IP67: Designed to meet the requirements of Environmental Ingress Protection Rating

Explosive Atmosphere approved per MIL-STD-810F, Procedure 1, NFPA 70E, Section 500, Class 1, Div. 2, Group D;

Shock Tested per IEC 60068-2-27, 60 g, 6 µs H.S., 3 axes, 18 total

Vibration Tested: Sine vibration per IEC 60068-2-6, 50 Hz to 150 Hz at 0.03 in. DA or 2 g, 20 sweep cycles

DISPLAY

Color Liquid Crystal Display: With 60 Hz up­date, user-selectable color schemes and bright­ness, and split-screen and full-screen modes.

Display Dimensions (W x H):320 pixels x 240 pixels color 101 mm (4 in.) x 75 mm (3 in.)

Baseline Break Mode: Zero cross points on the RF waveform are shown as zero points in fullwave mode.

Amplitude Grid Modes: 100% or 110% am­plitude display

Time Base Grid Modes: Standard 0 to 10 divi­sion, Sound Path mode divides range into five (5) equal sections with grid lines; leg mode displays sound path legs as grid lines.

PULSER

Tunable Square Wave Pulser

PRF: User selectable or auto from 10 Hz to 1 kHz

Energy Settings: 50 V to 475 V in 25 V incre­ments

Pulse Width: Adjustable from 30 ns to 10,000 ns (0.1 MHz) with PerfectSquare™ Technology

Damping: 50 Ω, 63 Ω, 150 Ω, 400 Ω

RECEIVER

Gain: 0 dB to 110 dB – Two user-defined gain step adjustments and presets above function keys

Total Instrument Bandwidth: 0.2 MHz to 26.5 MHz at –3 dB

Digital Filter Settings:

• 0.2 MHz to 10.0 MHz• 2.0 MHz to 21.5 MHz

• 0.2 MHz to 1.2 MHz • 5.0 MHz to 15.0 MHz

• 0.5 MHz to 4.0 MHz• 8.0 MHz to 26.5 MHz

• 1.5 MHz to 8.5 MHz

Rectification: Fullwave, positive halfwave, negative halfwave, RF

System Linearity: Horizontal: ±0.2% FSWvertical: 0.25% FSH, amplifier accuracy ±1dB

Reject: 0% to 80% full-screen height with visual warning

CALIBRATION

Automated Distance Calibration for Velocity and Zero Offset

Test Modes: Pulse Echo, Dual, or Through Transmission

Units: Millimeters, inches, or microseconds

Range: 1.86 mm to 13,400 mm (0.073 in. to 527 in.)

Velocity: 0.025 in./µs to 0.6000 in./µs (635 m/s to 15,240 m/s)

Zero Offset: 0 µs to 4950 µs

Display Delay:–59 mm to 12700 mm (–2.323 in. to 500 in.)

Refracted Angle: 10° to 85° in 0.1° resolution

MEASUREMENTS

Types: Thickness, Sound Path, Projection, Depth, Amplitude, Time-Of-Flight for both Gate 1 and Gate 2

Echo-To-Echo: Standard 

Five Measurement Display Locations: User selects up to five measurements from either gate to display on the live screen.

DAC/TVG Standard: Up to 50 points captured, ASME, ASME III, JIS, 80% to 20%, Custom DAC, and TVG Table. 110 dB dynamic range, 100 dB per µs adjustment, full gain, range, and delay adjustments during setup, view switchable between DAC/TVG

Custom DAC with up to six warning curves from +24 dB to –24 dB

TVG Table setup for advanced Time Varied Gain applications. Also allows TVG setups to be built from DGS/AVG diagrams.

Amplitude Measurement: 0% to 110% full- screen height with 0.25% resolution

Curved Surface Correction for Angle Beam measurements standard

X-Value Correction for distance from Beam Index Point to front of transducer

GATES

Two Fully Independent Gates for Echo Height and Time-Of-Flight

Gate Start: Variable over entire displayed range

Gate Width: Variable from Gate Start to end of displayed range

Gate Height: Variable from 2% to 95% full- screen height

Alarms: Positive and negative thresholds; minimum depth on Gate 1 and Gate 2

Zoom: Displayed range is Gate 1 width

INSTRUMENT INPUTS/OUTPUTS

USB Client Port: For communication with GageView Pro

USB Host Port: Allows direct printing to any PCL5 compatible laser or inkjet printer as well as data storage on USB drives

LEMO® Hardware I/O (optional): Alarm out­puts, trigger in/out, encoder interface

VGA Output Port: Connects to standard VGA monitor or projector

Analog Output Port (optional): Selectable voltage output of depth or amplitude data

DATA STORAGE

Up to 10,000 IDs with waveforms, measure­ments, and setup parameters

WARRANTY One-year limited warranty.

STANDARD INCLUSIONS

EPOCH XT Base Instrument Includes:

EP-MCA: AC adaptor

EPXT-TC: Transport case

EPXT-MAN: Instrument operating manual

EPXT-HS: Bidirectional hand strap

EPXT-PS: Rubber coated stainless steel pipe stand

EPXT-BAT-L: Lithium-ion or EPXT-BAT-N: Nickel metal hydride battery

Cap(s) for transducer connectors

Complete Ultrasonic Testing Machine



Copyright Notice @ 2008-2022 ECOL Limited and/or its subsidiaries and licensors. All rights reserved.