- Testing Equipment[6]
- Boiler Parts[1]
- Boilers[5]
- Other Measuring & Analysing Instruments[6]
- Other Lab Supplies[1]
- Other Electronic Measuring Instruments[6]
- Industrial Metal Detectors[1]
- Width Measuring Instruments[3]
- Other Measuring & Gauging Tools[3]
- Gauges[3]
- Hardness Testers[2]
- Access Control System[1]
- Other Machinery[4]
- Instrument Parts & Accessories[4]
- Radiology Equipments & Accessories[6]
- Inspection & Quality Control Services[1]
- Other Access Control Products[1]
- Contact Person : Mr. Li David
- Company Name : Dandong Flaw Detector Equipment Co., Ltd.
- Tel : 86-415-2883568,13942562233
- Fax : 86-415-2825993
- Address : Liaoning,Dandong,70-2# Tianhougong St. Dandong,Liaoning,P.R.of China
- Country/Region : China
- Zip : 118000
Related Product Searches:Complete Ultrasonic Testing Machine,High Quality,Testing Machine, Ultrasonic NDT,Epoch_XT
Testing Machine
EPOCH XT Specifications
GENERAL
EN12668-1 Compliant
Weight: 2.1 kg (4.7 lb) with lithium-ion battery
Dimensions (H x W xD): 277 mm x 150 mm x 51 mm (at hand), 71 mm (at display); 10.9 in. x 5.9 in. x 2 in. (at hand), 2.8 in. (at display)
Keypad: English, International, Japanese, or Chinese
Languages: English, Spanish, French, German,Italian, Japanese, Chinese, Russian, Korean, Norwegian, Swedish
Transducer Connections: BNC or Number 1 LEMO
Battery: Choice of lithium-ion, nickel metal hydride, and alkaline C-cells
Battery Operating Time: Lithium ion: 9 to 10 hoursNiMH: 5 hours; C-cells: 1 to 2 hours
Power Requirements: AC Mains: 100 VAC to 120 VAC, 200 VAC to 240 VAC, 50 Hz to 60 Hz
ENVIRONMENTAL RATINGS
IP67: Designed to meet the requirements of Environmental Ingress Protection Rating
Explosive Atmosphere approved per MIL-STD-810F, Procedure 1, NFPA 70E, Section 500, Class 1, Div. 2, Group D;
Shock Tested per IEC 60068-2-27, 60 g, 6 µs H.S., 3 axes, 18 total
Vibration Tested: Sine vibration per IEC 60068-2-6, 50 Hz to 150 Hz at 0.03 in. DA or 2 g, 20 sweep cycles
DISPLAY
Color Liquid Crystal Display: With 60 Hz update, user-selectable color schemes and brightness, and split-screen and full-screen modes.
Display Dimensions (W x H):320 pixels x 240 pixels color 101 mm (4 in.) x 75 mm (3 in.)
Baseline Break Mode: Zero cross points on the RF waveform are shown as zero points in fullwave mode.
Amplitude Grid Modes: 100% or 110% amplitude display
Time Base Grid Modes: Standard 0 to 10 division, Sound Path mode divides range into five (5) equal sections with grid lines; leg mode displays sound path legs as grid lines.
PULSER
Tunable Square Wave Pulser
PRF: User selectable or auto from 10 Hz to 1 kHz
Energy Settings: 50 V to 475 V in 25 V increments
Pulse Width: Adjustable from 30 ns to 10,000 ns (0.1 MHz) with PerfectSquare™ Technology
Damping: 50 Ω, 63 Ω, 150 Ω, 400 Ω
RECEIVER
Gain: 0 dB to 110 dB – Two user-defined gain step adjustments and presets above function keys
Total Instrument Bandwidth: 0.2 MHz to 26.5 MHz at –3 dB
Digital Filter Settings:
• 0.2 MHz to 10.0 MHz• 2.0 MHz to 21.5 MHz
• 0.2 MHz to 1.2 MHz • 5.0 MHz to 15.0 MHz
• 0.5 MHz to 4.0 MHz• 8.0 MHz to 26.5 MHz
• 1.5 MHz to 8.5 MHz
Rectification: Fullwave, positive halfwave, negative halfwave, RF
System Linearity: Horizontal: ±0.2% FSWvertical: 0.25% FSH, amplifier accuracy ±1dB
Reject: 0% to 80% full-screen height with visual warning
CALIBRATION
Automated Distance Calibration for Velocity and Zero Offset
Test Modes: Pulse Echo, Dual, or Through Transmission
Units: Millimeters, inches, or microseconds
Range: 1.86 mm to 13,400 mm (0.073 in. to 527 in.)
Velocity: 0.025 in./µs to 0.6000 in./µs (635 m/s to 15,240 m/s)
Zero Offset: 0 µs to 4950 µs
Display Delay:–59 mm to 12700 mm (–2.323 in. to 500 in.)
Refracted Angle: 10° to 85° in 0.1° resolution
MEASUREMENTS
Types: Thickness, Sound Path, Projection, Depth, Amplitude, Time-Of-Flight for both Gate 1 and Gate 2
Echo-To-Echo: Standard
Five Measurement Display Locations: User selects up to five measurements from either gate to display on the live screen.
DAC/TVG Standard: Up to 50 points captured, ASME, ASME III, JIS, 80% to 20%, Custom DAC, and TVG Table. 110 dB dynamic range, 100 dB per µs adjustment, full gain, range, and delay adjustments during setup, view switchable between DAC/TVG
Custom DAC with up to six warning curves from +24 dB to –24 dB
TVG Table setup for advanced Time Varied Gain applications. Also allows TVG setups to be built from DGS/AVG diagrams.
Amplitude Measurement: 0% to 110% full- screen height with 0.25% resolution
Curved Surface Correction for Angle Beam measurements standard
X-Value Correction for distance from Beam Index Point to front of transducer
GATES
Two Fully Independent Gates for Echo Height and Time-Of-Flight
Gate Start: Variable over entire displayed range
Gate Width: Variable from Gate Start to end of displayed range
Gate Height: Variable from 2% to 95% full- screen height
Alarms: Positive and negative thresholds; minimum depth on Gate 1 and Gate 2
Zoom: Displayed range is Gate 1 width
INSTRUMENT INPUTS/OUTPUTS
USB Client Port: For communication with GageView Pro
USB Host Port: Allows direct printing to any PCL5 compatible laser or inkjet printer as well as data storage on USB drives
LEMO® Hardware I/O (optional): Alarm outputs, trigger in/out, encoder interface
VGA Output Port: Connects to standard VGA monitor or projector
Analog Output Port (optional): Selectable voltage output of depth or amplitude data
DATA STORAGE
Up to 10,000 IDs with waveforms, measurements, and setup parameters
WARRANTY One-year limited warranty.
STANDARD INCLUSIONS
EPOCH XT Base Instrument Includes:
EP-MCA: AC adaptor
EPXT-TC: Transport case
EPXT-MAN: Instrument operating manual
EPXT-HS: Bidirectional hand strap
EPXT-PS: Rubber coated stainless steel pipe stand
EPXT-BAT-L: Lithium-ion or EPXT-BAT-N: Nickel metal hydride battery
Cap(s) for transducer connectors